4042

COUNTY LOCAL LAWS

other unusual disturbances as may arise from time to
time.

SECTION 2. AND BE IT FURTHER ENACTED, That this
Ordinance shall take effect forty—five (45) days from the
date it becomes law.

READ AND PASSED July 2, 1973.

Bill No. 76-73

AN ORDINANCE to repeal Section 3-208(53) of the Anne
Arundel County Code (1967 Edition and Supplements),
Title 3, "Buildings", Subtitle 2, "Structural
Requirements", and to enact new Section 3—208(53) in
lieu thereof, to stand in the place of the section
repealed, to establish new standards for grounding
electrodes.

SECTION 1. BE IT ENACTED BY THE COUNTY COUNCIL OF
ANNE ARUNDEL COUNTY, MARYLAND, That Section 3-208(53) of
the Anne Arundel County Code (1967 Edition and
Supplements), Title 3, "Buildings", Subtitle 2,
"Structural Requirements", be, and it is hereby repealed,
and that new Section 3—208(53) be, and it is hereby
enacted in lieu thereof, to stand in the place of the
Section repealed, and to read as follows:

Section 3-208

(53) IMMEDIATELY BELOW SUBSECTION 1502.2, INSERT
THE FOLLOWING NEW SUBSECTION 1502.3:

"SUBSECTION 1502.3 - GROUNDING ELECTRODE: EXPANDING
USE OF NON-METALLIC PIPING FOR WATER SYSTEMS AND
INSULATING COUPLINGS ON METAL WATER SYSTEMS MAKES IT MORE
IMPORTANT THAT THE WATER PIPING WITHIN A BUILDING BE
ADEQUATELY GROUNDED WITHOUT DEPENDING ON CONNECTIONS TO
AN OUTSIDE PIPING SYSTEM. IN ORDER TO PROVIDE ADEQUATE
ELECTRICAL GROUND A CONCRETE ENCASED ELECTRODE SHALL BE
PROVIDED. SAID ELECTRODE SHALL CONSIST A MINIMUM
HORIZONTAL LENGTH OF TWENTY FEET (20') OF PARE COPPER
CONDUCTOR, NOT SMALLER THAN NO. 4, ENCASED BY AT LEAST
TWO INCHES (2") OF CONCRETE AND LOCATED WITHIN AND
CENTERED NEAR THE BOTTOM OF A FOUNDATION FOOTING THAT IS
IN DIRECT CONTACT WITH THE EARTH. THE ELECTRODE SHALL BE
LOCATED NEAR THE EXPECTED LOCATION OF THE SERVICE PANEL
AND SHALL BE EXTENDED TO PROVIDE A MINIMUM OF SIX INCHES
(6") OF CONDUCTOR ABOVE THE FINISHED CONCRETE FLOOR. IF

 

clear space
clear space
white space

Please view image to verify text. To report an error, please contact us.
Session Laws, 1974
Volume 713, Page 4042   View pdf image
 Jump to  
  << PREVIOUS  NEXT >>


This web site is presented for reference purposes under the doctrine of fair use. When this material is used, in whole or in part, proper citation and credit must be attributed to the Maryland State Archives. PLEASE NOTE: The site may contain material from other sources which may be under copyright. Rights assessment, and full originating source citation, is the responsibility of the user.


Tell Us What You Think About the Maryland State Archives Website!



An Archives of Maryland electronic publication.
For information contact mdlegal@mdarchives.state.md.us.

©Copyright  Cannot perform flastmod(): Win32 Error Code = 2

Maryland State Archives