clear space clear space clear space white space
A
 r c h i v e s   o f   M a r y l a n d   O n l i n e

PLEASE NOTE: The searchable text below was computer generated and may contain typographical errors. Numerical typos are particularly troubling. Click “View pdf” to see the original document.

  Maryland State Archives | Index | Help | Search
search for:
clear space
white space
Session Laws, 2005
Volume 752, Page 3639   View pdf image
 Jump to  
  << PREVIOUS  NEXT >>
clear space clear space clear space white space
ROBERT L. EHRLICH, JR., Governor                            S.B. 464
(v) red and green traffic signal modules shall: 1.       meet the requirements of the "Energy Star Program
Requirements for Traffic Signals" developed by the U.S. Environmental Protection
Agency that took effect in February 2001; and 2.       be installed with compatible, electrically-connected signal
control interface devices and conflict monitoring systems; (vi) illuminated exit signs shall meet the requirements of the
"Energy Star Program Requirements for Exit Signs - VERSION 2.0" developed by the
U.S. Environmental Protection Agency that took effect on January 1, 1999; (vii) commercial refrigeration cabinets shall meet the requirements
shown in the following Table in which "V" means total volume in cubic feet and "AV"
means adjusted volume which is the sum of the volume of refrigerated space and 1.63
times the volume of freezer space: Equipment Type                                                                     Maximum Daily Energy Consumption
(kilowatt hours) Reach-in cabinets, pass-through cabinets, and                            0.125V + 2.76 roll-in or roll-through cabinets that are refrigerators
with solid doors Reach-in cabinets, pass-through cabinets, and                            0.172V + 4.77 roll-in or roll-through cabinets that are refrigerators
with transparent doors Reach-in cabinets, pass-through cabinets, and                            0.398V + 2.28 roll-in or roll-through cabinets that are freezers
with solid doors Reach-in cabinets, pass-through cabinets, and                            0.940V + 5.10 roll-in or roll-through cabinets that are freezers
with transparent doors Reach-in cabinets that                                                             0.273AV + 1.65 are refrigerator-freezers with solid doors (viii) large packaged air-conditioning equipment shall meet the Tier
II requirements of the "Minimum Equipment Efficiencies for Unitary Commercial Air
Conditioners" or "Minimum Equipment Efficiencies for Heat Pumps", as appropriate,
developed by the Consortium for Energy Efficiency, Boston, Massachusetts, as in
effect on January 1, 2002; and (ix) commercial clothes washers shall have a minimum modified
energy factor of 1.26 and a maximum water consumption factor of 9.5, as measured in
accordance with the federal test method for clothes washers as defined in 10 C.F.R.
Section 430.23(j) (Appendix J1 to Subpart B of Part 430) (2001). (d) (1) (i) Except as provided in subparagraphs (ii) and (iii) of this
paragraph, on or after March 1, 2005, a new product of any type set forth in - 3639 -


 
clear space
clear space
white space

Please view image to verify text. To report an error, please contact us.
Session Laws, 2005
Volume 752, Page 3639   View pdf image
 Jump to  
  << PREVIOUS  NEXT >>


This web site is presented for reference purposes under the doctrine of fair use. When this material is used, in whole or in part, proper citation and credit must be attributed to the Maryland State Archives. PLEASE NOTE: The site may contain material from other sources which may be under copyright. Rights assessment, and full originating source citation, is the responsibility of the user.


Tell Us What You Think About the Maryland State Archives Website!



An Archives of Maryland electronic publication.
For information contact mdlegal@mdarchives.state.md.us.

©Copyright  August 17, 2024
Maryland State Archives