COUNTY LOCAL LAWS

(39)   SECTION 1600.5.1

(A) WHEN SUBSURFACE IRRIGATION IS CONTEMPLATED,
TEST PIT SHALL BE PREPARED ONE FOOT (1') SQUARE BUT NOT
LESS THAN TWO FOOT (2') DEEP. AT THE TIME OF CONDUCTING
THE PERCOLATION TEST FOR A DRYWELL, A CLEAN HOLE ONE FOOT
(1') SQUARE AND ONE FOOT (1') DEEP SHALL BE PREPARED IN
THE BOTTOM OF THE TEST PIT.

(40)   SECTION 1600.8.3 DEPTH BELOW GRADE

THE TOP SHALL BE NOT MORE THAN TWELVE INCHES (12")
BELOW FINISHED GRADE, UNLESS OTHERWISE PERMITTED BY THE
APPROVING AUTHORITY.

(41)   TABLE 1600.8.4 DESIGN OF SEEPAGE PIT COVERS

COVES

REINFORCING STEEL
REQUIRED IN

PIT

PIT WALL

COVER

WGT.

TWO PERPENDICULAR

DIAMETER

THICKNESS

THICKNESS

(LBS.)

DIRECTIONS

5 FT.

6"

5"

1230

#5 9 10 1/2"

6 FT.

8"

5"

1770

#5 9 9"

8 FT.

8"

6"

3780

#5 @ 7 1/2" C/C

10 FT.

8"

8"

7850

#5 9 6 1/2" C/C

(42)   SECTION 1600.9

(C) THE MINIMUM SIZE PIPE SHALL BE FOUR INCHES (4")
AND THE MINIMUM SPACING REQUIREMENTS FOR DISPOSAL FIELDS
SHALL CONFORM TO THOSE SET FORTH IN TABLE 1600.9D.

(43)       SECTION 1600.9

(E)       DISPOSAL LINES SHALL BE CONSTRUCTED OF NOT LESS
THAN FOUR INCH (4") PIPE OF OPEN JOINTED OR HORIZONTALLY
SPLIT OR PERFORATED CLAY TILE, PERFORATED ASBESTOS
CEMENT, PERFORATED BITUMINIZED FIBER OR PLASTIC PIPE OR
OPEN JOINTED CAST IRON SOIL PIPE. IF CLAY TILE OF OPEN
JOINTED CAST IRON SOIL PIPE IS USED, THE SECTIONS SHALL
BE SPACED NOT MORE THAN ONE-HALF INCH (1/2") APART, AND
THE UPPER HALF OF THE JOINT SHALL BE PROTECTED BY
ASPHALT-TREATED PAPER WHILE THE PIPING IS BEING COVERED.

(44)   SECTION 1600.9

(F)   THE TRENCH BOTTOM SHALL BE UNIFORMLY GRADED TO
SLOPE FROM A MINIMUM OF ONE INCH (1") TO A MAXIMUM OF
FOUR INCHES (4") PER ONE HUNDRED FEET (100').

(45)   SECTION 1600.11 PIPING MATERIAL

ALL PIPING FROM BUILDING DRAIN TO THE DISTRIBUTION

 

clear space
clear space
white space

Please view image to verify text. To report an error, please contact us.
Session Laws, 1975
Volume 716, Page 5010   View pdf image
 Jump to  
  << PREVIOUS  NEXT >>


This web site is presented for reference purposes under the doctrine of fair use. When this material is used, in whole or in part, proper citation and credit must be attributed to the Maryland State Archives. PLEASE NOTE: The site may contain material from other sources which may be under copyright. Rights assessment, and full originating source citation, is the responsibility of the user.


Tell Us What You Think About the Maryland State Archives Website!



An Archives of Maryland electronic publication.
For information contact mdlegal@mdarchives.state.md.us.

©Copyright  November 18, 2025
Maryland State Archives