2586

COUNTY LOCAL LAMS

PERMITTED IN SWIMMING POOLS WHICH, UNDER ANY
CONDITIONS, WILL ALLOW SEWAGE OR OTHER POLLUTED WATER
TO ENTER THE POOL OR THE RECIRCULATION SYSTEM
DIRECTLY, OR UNDER WHICH WATER FROM THE RECIRCULATION
SYSTEM OR POOL CAN ENTER THE WATER SUPPLY SYSTEM FROM
WHICH THE MAKE-UP WATER SUPPLY IS TAKEN. ALL POOL
DRAINS SHALL BE PROVIDED WITH AN ADEQUATE AIR-GAP
PROPERLY LOCATED TO PREVENT ANY SEWAGE OR OTHER
POLLUTED WATER FROM ENTERING THE POOL. ALL BACKWASH
FROM POOL FILTERS MUST BE DISCHARGED INTO APPROVED
SANITARY DISPOSAL SYSTEMS UNLESS DISCHARGE IS LESS
THAN FIVE (5) GALLONS. SEE SECTION 900.17."

(38) "SECTION 1800.2

(C) REFERENCE HANDBOOK

APPENDIX "A" OF THE "REFERENCE

HANDBOOK" PUBLISHED BY THE NATIONAL SWIMMING POOL
INSTITUTE IS RECOMMENDED AS AN EXCELLENT GUIDE FOR
SWIMMING POOL DESIGN AND OPERATION. ANOTHER EXCELLENT
REFERENCE IS A BOOK TITLED "SWIMMING POOL OPERATION",
12TH EDITION 1971, PUBLISHED BY THE WASHINGTON STATE
PUBLIC HEALTH ASSOCIATION."

(C) NEW SECTIONS 201.3.4, 401.8, 401.9, 806,
901.1B, 1600.8G AND 1600.5.1D BE, AND THEY ARE HEREBY
ADDED TO THE SEVENTH DRAFT OF THE PROPOSED REVISION OF
THE STATE PLUMBING CODE, TO READ AS FOLLOWS:

(1)   "SECTION 201.3.4 FIRE RATING

All thermoplastic pipe penetrating a

fire—rated wall or ceiling shall meet the integrity of
the wall or ceiling, as evidenced by a test report
from a nationally recognized fire testing laboratory
indicating that said pipe will not spread fire or
significant quantities of smoke from one floor to
another during a two (2) hour fire, provided the
material is installed in accordance with the results
of the test."

(2)   "Section 401.8 ABS OR PVC PLASTIC DWV
TO OTHER                                                                              MATERIAL

(a) ABS or PVC DWV joints when

threaded shall use the proper male or female threaded
adapter. Use only approved thread tape or lubricant
seal as Teflon tape, petroleum jelly, or other
approved materials as recommended by the manufacturer.

 

clear space
clear space
white space

Please view image to verify text. To report an error, please contact us.
Session Laws, 1973
Volume 709, Page 2586   View pdf image
 Jump to  
  << PREVIOUS  NEXT >>


This web site is presented for reference purposes under the doctrine of fair use. When this material is used, in whole or in part, proper citation and credit must be attributed to the Maryland State Archives. PLEASE NOTE: The site may contain material from other sources which may be under copyright. Rights assessment, and full originating source citation, is the responsibility of the user.


Tell Us What You Think About the Maryland State Archives Website!



An Archives of Maryland electronic publication.
For information contact mdlegal@mdarchives.state.md.us.

©Copyright  August 17, 2024
Maryland State Archives