2559
ANNE ARUNDEL COUNTY
CHILDREN SHALL BE EQUIPPED WITH AN APPROVED FIRE ALARM
SYSTEM."
(46) Strike all of Subsection 1219.14 and insert
a new Subsection 12 19.14 in lieu thereof, to stand in
the place of the subsection so stricken, and to read
as follows:
"SUBSECTION 1219.14. SCHOOL BUILDINGS:
ALL SCHOOL BUILDINGS (USE GROUP F-4) WITH PROVISION
FOR MORE THAN THIRTY (30) CHILDREN SHALL BE EQUIPPED
WITH AN APPROVED FIRE ALARM SYSTEM."
(47) Strike all of Subsection 1219.17 and insert
a new Subsection 1219.17 in lieu thereof, to stand in
the place of the subsection so stricken, and to read
as follows:
"SUBSECTION 1219.17. BUSINESS BUILDINGS:
ALL OFFICE BUILDINGS MORE THAN THREE (3) STORIES OR
THIRTY FEET (30') IN HEIGHT WITH AN OCCUPANCY LOAD OF
MORE THAN FIFTY (50) PERSONS ABOVE THE FIRST FLOOR
SHALL BE EQUIPPED WITH EITHER AN AUTOMATIC SPRINKLER
SYSTEM OR AN APPROVED FIRE ALARM SYSTEM."
(48) Strike all of Subsection 1308.1 and insert
a new Subsection 1308.1 in lieu thereof, to stand in
the place of the subsection so stricken, and to read
as follows:
"SUBSECTION 1308.1 TEMPORARY SUPPORT: THE
PROVISIONS OF THIS SUBSECTION SHALL APPLY TO ALL
EXCAVATIONS WHICH ARE FOUR FEET (4') OR MORE BELOW THE
EXISTING GRADE LEVEL. UNTIL PERMANENT SUPPORT HAS
BEEN PROVIDED, ALL EXCAVATIONS SHALL BE SAFEGUARDED
AND PROTECTED BY THE PERSON CAUSING THE EXCAVATIONS TO
BE MADE, TO AVOID ALL DANGER TO LIFE OR LIMB. WHERE
NECESSARY, SUCH EXCAVATIONS SHALL BE RETAINED BY
TEMPORARY RETAINING WALLS, SHEET-PILING AND BRACING OR
OTHER APPROVED METHOD TO SUPPORT THE ADJOINING EARTH.
TEMPORARY SUPPORT NEED NOT BE PROVIDED IF THE SIDES OF
THE EXCAVATION ARE SLOPED TO AN ANGLE OF FORTY-FIVE
DEGREES (45°) OR MORE AWAY FROM VERTICAL."
(49) Strike all of Subsection 1308.21 and insert
a new Subsection 1308.21 in lieu thereof, to stand in
the place of the subsection so stricken, and to read
as follows:
"SUBSECTION 1308.21. DEEP EXCAVATIONS:
|