(v) A PROPOSED TIME SCHEDULE FOR EACH OF SAID
PHASES.

(1) Recommendations (4) THE PROFESSIONAL ENGI-
NEER'S RECOMMENDATIONS to guide the design, construction
and inspection of the proposed facility SITE. Said recommendations
shall take into consideration the following:

(a)    Cleaning, grubbing, stripping, keying and undercutting for
the acceptance of fill.

(b)     Compaction requirement for all classes of fill.

(c)    Allowable slope angle and bench requirements for cut and
fill slopes.

(d) Allowable soil pressure for foundations on natural ground

and/or fill.

(d)    Erosion control during both the construction and the life
of the facility.

(e)    Ground water control during both the construction and the
life of the facility.

(f)    Testing and inspection requirements of this Subtitle.
(h) Pavement design (if included in the project).

(g) Location, handling UTILIZATION and repair RESTORA-
TION of excess borrow material and/or spoil areas.

(5) A RECORD OF FIELD OBSERVATIONS, FIELD TEST
DATA (SUCH AS BEHAVIOR OF ADJACENT OR NEARBY
STRUCTURES; GEOLOGIC HISTORY AND ORIGIN OF SOIL;
FIELD TEST BORING LOG GIVING CLASSIFICATION, STAN-
DARD PENETRATION DATA AND WATER LEVEL OBSER-
VATIONS; FIELD TEST RESULTS FOR THE PILE LOAD TEST,
PLATE LOAD TEST AND OTHERS AS NECESSARY), LAB-
ORATORY TEST DATA (SUCH AS MOISTURE DENSITY
CURVES, GRAIN SIZE CURVES, SHEAR STRENGTH TESTS,
MOISTURE CONTENT, AND CONSOLIDATION TEST RE-
SULTS), AND PROJECT CHARACTERISTICS (SUCH AS
THOSE AFFECTING SOIL AND FOUNDATION DESIGN; SEN-
SITIVITY TO SETTLEMENT AND DESIGN LOADS; FACTOR
OF SAFETY AGAINST FAILURE; CONSEQUENCES OF FAIL-
URE AND MERITS OF PROGRAMMED MAINTENANCE;
LOCATION OF BORROW PITS ON SITE OR LOCATION WHERE
SUITABLE FILL WILL BE OBTAINED) UPON WHICH THE
PROFESSIONAL ENGINEER'S RECOMMENDATIONS WERE
BASED.

Section 12-2007. REFERRAL OF PLANS.
No permit shall be issued unless:

(1) the proposed grading EROSION and sediment control
measures have been approved by the Anne Arundel County Soil Con-
servation District; and

 

clear space
clear space
white space

Please view image to verify text. To report an error, please contact us.
Session Laws, 1972
Volume 708, Page 2385   View pdf image
 Jump to  
  << PREVIOUS  NEXT >>


This web site is presented for reference purposes under the doctrine of fair use. When this material is used, in whole or in part, proper citation and credit must be attributed to the Maryland State Archives. PLEASE NOTE: The site may contain material from other sources which may be under copyright. Rights assessment, and full originating source citation, is the responsibility of the user.


Tell Us What You Think About the Maryland State Archives Website!



An Archives of Maryland electronic publication.
For information contact mdlegal@mdarchives.state.md.us.

©Copyright  August 17, 2024
Maryland State Archives