2583
ANNE ARUNDEL COUNTY
2 5 FT.
3 6 FT.
4 10 FT.
NOTE: THE DEVELOPED LENGTH BETWEEN THE TRAP OF A
WATER CLOSET (MEASURED FROM TOP OF FLOOR FLANGE
TO INNER EDGE OF THE VENT) AND ITS VENT SHALL NOT
EXCEED SIX FEET (6')."
(25) "SECTION 1600.2
(B) APPLICATIONS FOR SAID PERMIT
SHALL BE IN A FORM REQUIRED BY THE APPROVING AUTHORITY
AND SHALL INCLUDE COMPLETE PLANS AND SPECIFICATIONS
FOR THE DESIRED INSTALLATION(S) . THE APPROVING
AUTHORITY SHALL REQUIRE A SOIL EVALUATION INCLUDING
PERCOLATION AND OTHER PERTINENT TESTS, SAID EVALUATION
TO BE CONDUCTED UNDER ITS SUPERVISION, WITH SUCH
INFORMATION TO BE MADE PART OF THE APPLICATION. WHEN
THERE IS EVIDENCE THAT A GEOGRAPHICAL FORMATION HAS A
HIGH AND FLUCTUATING WATER TABLE DURING SPECIFIED
MONTHS OF THE YEAR, THE APPROVING AUTHORITY MAY
INDICATE THE TIMES DURING WHICH THE TESTS ARE TO BE
MADE."
(26) "SECTION 1600.2
(C) PERCOLATION TESTS SHALL BE
CONSIDERED INVALID AFTER ONE (1) YEAR FROM THE DATE OF
TESTING AND SHALL BE MADE IN SUFFICIENT NUMBER AND AT
SUCH LOCATIONS AS SPECIFIED BY THE APPROVING AUTHORITY
TO ASSURE A RELIABLE DETERMINATION OF SUB-SURFACE
CONDITIONS. THE PERCOLATION DRAWDOWN RATE MAY RANGE
BETWEEN 0 AND 30 MINUTES. THE RESULTS OF PERCOLATION
TESTS SHALL BE CONSIDERED IN CONJUNCTION WITH
AVAILABLE INFORMATION ON TOPOGRAPHY, SOIL TYPE AND
CONDITION, SURFACE AND SUBSURFACE DRAINAGE CONDITIONS,
WATER TABLE LEVEL, AND THE HISTORY OF FAILURE OF
SEPTIC SYSTEMS IN SURROUNDING AREAS, AND SOIL MAPS
DATA."
(27) "SECTION 1600.2
(D) (I) WHEN, UPON REVIEW OF THE
APPLICATION, THE APPROVING AUTHORITY IS SATISFIED THAT
THE PROPOSED DESIGN IS ADEQUATE, A WRITTEN PERMIT TO
PROCEED WITH CONSTRUCTION SHALL BE ISSUED. THE LENGTH
OF TIME A PERMIT IS TO RUN SHALL BE SPECIFIED IN SUCH
PERMIT AND SHALL NOT EXCEED ONE (1) YEAR. SAID PERMIT
SHALL AUTOMATICALLY BECOME INOPERATIVE AT THE
|